Specifications
Nominal voltage, V | 12 |
Nominal capacity, Ah | 80 |
Design life, years | 12 |
Technology | AGM |
Length, mm | 350 |
Width, mm | 167 |
Height,mm | 179 |
Height without terminals, mm | 179 |
Height max,mm | 179 |
Weight, kg | 24,2 (±3%) |
Description
ASTERION HRL-X are sealed maintenance-free lead-acid batteries with gas recombination system (VRLA). Are manufactured by AGM technology (electrolyte absorbed in glass fiber separators). Thanks to the use of modern technologies in production, batteries demonstrate high operation stability and highest quality. HR refers to a range of ASTERION UPS series, specifically designed for use in UPS Data Centers, communication systems and other equipment. The series is highly reliable and has a service-life up to 12 years.
Battery construction
Element | Positive plate | Negative plate | Case | Lid | Valve | Terminal | Separator | Electrolyte |
---|---|---|---|---|---|---|---|
Material | Lead dioxide | Lead | ABS | Rubber | Copper | Fiberglass | Acid |
Performance & characteristics:
- AGM technology allows to recombinate 99% of the generated gas;
- No restrictions on air transportation;
- Compliance with the UL requirements;
- Lead plates, alloyed by calcium, provide high energy density;
- Maintenance-free. Do not require distillate topping;
- Long service life;
- The battery case is made of flame-retardant ABS plastic.
Application:
- Uninterruptable power supply
- Back up power supply
- Communication system
- Power engineering facilities
- Renewable energy systems
Operating temperature range
Discharge | -20÷60 |
---|---|
Charge | -10÷60 |
Storage | -20÷60 |
Cycle mode (2,35÷2,4 V/cell): | |
Maximum discharge current | 750 А |
Temperature correction factor | 30 mV/°С |
Standby mode (2,27÷2,3 V/cell): | |
Temperature correction factor | 20 mV/°С |
Discharge Constant Current, A ( 25°С)
V/cell | 5 min | 10 min | 15 min | 30 min | 45 min | 1 h | 3 h | 5 h | 10 h |
---|---|---|---|---|---|---|---|---|---|
1.60V | 276 | 213 | 168 | 104 | 75,8 | 59,9 | 21,9 | 15,7 | 9,01 |
1.65V | 260 | 201 | 160 | 99,0 | 71,9 | 58,0 | 21,4 | 15,1 | 8,68 |
1.70V | 245 | 189 | 151 | 93,8 | 68,2 | 54,8 | 20,9 | 14,5 | 8,38 |
1.75V | 227 | 178 | 143 | 88,7 | 64,8 | 52,0 | 19,9 |
13,8 |
8,09 |
1.80V | 219 | 172 | 137 | 86,0 | 63,1 | 50,2 | 19,5 |
13,5 |
8,00 |
Discharge Constant Power, W/cell ( 25°С)
V/cell | 5 min | 10 min | 15 min | 30 min | 45 min | 1 h | 3 h | 5 h | 10 h |
---|---|---|---|---|---|---|---|---|---|
1.60V | 499 | 377 | 290 | 178 | 133 | 104 | 38,7 | 28,2 | 14,8 |
1.65V | 483 | 362 | 279 | 172 |
129 |
102 |
37,9 | 27,8 | 14,7 |
1.70V | 462 | 351 | 270 | 168 | 125 | 97,2 | 37,5 | 27,0 | 14,5 |
1.75V | 423 | 337 | 260 | 160 | 121 |
95,4 |
36,7 |
26,6 | 14,4 |
1.80V | 418 | 321 | 250 | 155 | 117 | 92,2 | 35,9 | 26,0 | 14,1 |